BA-en-3041-2008_PC 43
Changing the setpoint
The setpoint can be changed with the +/- buttons. Depending on the
selected mode, you can change the voltage or current setpoint (voltage
constant starting at 1500 V, current constant starting at 50 µA).
The buttons can be pressed individually / pressed and held.
The setpoint can only be changed once the Setup menu has been closed.
The LED bar switches from showing the actual value to showing the set-
point. When you release the button, the bar automatically changes back to
the actual value.
Changing the bar indication mode
Press the kv / mA button to switch from the high voltage indicator to the
current indicator or vice versa.
The indication mode changes every time you press the button, but only if
the Setup menu has been deactivated.
Switching the high voltage output ON and OFF
Press the ON/OFF button to activate or deactivate the high voltage output;
the setting “Release via integrated control elements” (default setting) must
be active.
Saving parameters
To save the entire parameter set, press and hold the OK button until the
LEDs flash twice.
Loading the factory settings
To load the factory settings, keep the +, – and OK buttons pressed until
the LEDs flash twice.