44 BA-en-3041-2008_PC
Acknowledging error / warning messages
Error and warning messages can be acknowledged with a common button
combination. Press and hold the three buttons Setup, OK and kV / mA
until the LEDs flash twice. The message is acknowledged following an
internal system check. A successful acknowledgment is confirmed via the
“Status” LED. If several errors or warnings have occurred, the message
must be acknowledged several times.
Setup Menu
the Setup menu offers several setting options.
• Discharging mode
only for variants with integrated active discharge
passive or active discharge
• Charging mode
Current- or voltage-constant charging
• Release option
Select the desired release option
• Analog setpoint
Select the mode for defining the setpoint via the analog interface
• CANopen® node address
Only possible in devices with an integrated CANopen® module. Set the
device’s node address for the CANopen® network.
• CANopen® transmission rate
Only in devices with an integrated CANopen® module. Select the
device’s transmission rate for the CANopen® network.
Go to the Setup menu by pressing and holding the Setup button until the
LEDs light up and the two LEDs kV and mA flash yellow together. Confirm
the entered settings with the OK button. The menu changes to the next
item. The process cannot be canceled; you must run through the entire
menu. When you exit the menu, the entered settings are saved automati-
cally.