A-4
EMC CLARiiON Server Support Products for Windows Installation Guide
Silent Installations and Removals
8. Click Cancel when the InstallShield wizard opens and click Yes to 
exit the setup.
9. Open a command line window, such as a DOS window.
10. Navigate to the directory where you unpacked the Initialization 
Utility files (the Initialization Utility Setup.exe file and all 
supporting files). You will run the Setup.exe file in the next 
section.
Creating a response file
1. Create a response file for the Initialization Utility by issuing the 
command below. The response file will store the setup 
configuration so that you can install the Initialization Utility on 
all attached Windows servers using one command. Since no input 
is required, this is referred to as a silent installation.
The command will launch an InstallShield Wizard. Pathnames or 
filenames containing spaces must be in double quotation marks, for 
example, "C:\my dir\my file.cfg".
Setup.exe -r -f1fullpath\responsefilename
where
-r
Indicates that a response file will be created.
-f1fullpath\responsefilename 
Specifies the full path name and filename of the target 
response file (in this case the Initialization Utility).
2. If the response file is not already in a shared directory, move it to 
a shared directory so that all attached Windows servers can 
access the file.