B.1.1 Volumetric Flow Rate
Volumetric Flow Rate - U.S. Customary units Equation B-3:

3
/
=
/
× 3600/ ×

2

4
×
1
12
2
=
/
×
2
 ×
3600 ×
4 × 12
2

2

2
=
/
×
2
 × 19.63495 
2
/ 
2
where
Q
ft
3
/hr
volumetric flow rate (ft
3
/h) (QMeter)
V
ft/s
gas flow velocity (ft/s) (AvgFlow)
p
geometric constant, pi (dimensionless) (3.14159265...)
Volumetric Flow Rate - Metric Units Equation B-4:
3
/
=
/
× 3600/ ×

2
4
=
/
×
2
×
3600 ×
4
/
=
/
×
2
× 20827.433 /
where
Q
m
3
/hr
volumetric flow rate (m
3
/h) (QMeter)
V
m/s
gas flow velocity(m/s) (AvgFlow)
p
geometric constant, pi (dimensionless) (3.14159265...)
D
m
pipe inside diameter (m) (PipeDiam)
B.2 Chord "L" dimension calculation