b. For Ethernet Connections: If you are connecting to the meter over an Ethernet
port, you should be able to connect with the same IP address as normal. If this is
unsuccessful, the meter may have defaulted to 192.168.135.100 with a subnet
of 255.255.255.0. Make sure your PC has a compatible address and attempt a
connection using this IP address.
2. Once your cabling and Meter Directory record are setup, attempt the connection to
the meter. You will receive a message Error 10001 opening database connection to,
click OK.
3. At the prompt to Attempt FTP-only connection, Click Yes. If successful, the Daniel
MeterLink
caption reads …Connected to <meter name>.
4. Go to Tools|Program Download to attempt the firmware upgrade again. If the
firmware upgrade is successful, the meter should start working as normally as the
meter's configuration is not normally lost.
5. If the configuration is lost, a configuration file was saved by the Program Download
utility on the initial firmware upgrade attempt.
Use Edit/Compare Configuration to write this saved configuration back to the
meter. The saved configuration files are typically stored in C:\Ultrasonic Data
\<MeterName>.
6. If the firmware upgrade fails again, contact Daniel Technical Support for assistance.
Contact information can be found in Daniel MeterLink
under the Help pull down
menu by selecting Technical Support. Or, in the Customer service in the preface of
this manual.
7.1.8
Communications analyzer
The Communications Analyzer is a Windows
®
application that displays "messages"
transmitted to and received from an addressable device, such as a Modbus slave, by
another Windows
®
application.
The messages are display from the oldest (at the top of the list) to the newest (at the
bottom of the list). The Communications Analyzer date and time stamps each message
displayed. After 4096 messages have been displayed, the oldest messages are cleared
from the list as new messages are added.
The Address combo box filters new messages so that only those with the selected address
(1-32) are displayed. By default, all addresses are displayed. The address filter does not
affect messages already displayed, only new messages.
Commands
124 3410 Series Gas Ultrasonic Flow meters