4.6.4 LCD display
Transmitters ordered with the LCD display will be shipped with the display installed.
Installing the display on an existing Rosemount 3051SMV requires the LCD display kit (part
number 03151-9193-0001 for aluminum housing and 03151-9193-0004 for stainless steel
(SST) housing).
About this task
Use the following procedure and Figure 4-13 to install the LCD display:
Procedure
1. If the transmitter is installed in a loop, then secure the loop and disconnect power.
2. Remove the transmitter cover on the feature board side (opposite the field
terminals side). Do not remove the instrument covers in explosive environments
when the circuit is live.
3. Engage the four-pin connector into the feature board and snap the LCD display into
place.
4. Install the display cover and tighten to ensure metal to metal contact in order to
meet flameproof/explosion-proof requirements.
Figure 4-13: Optional LCD Display
A. Feature board
B. LCD display
C. Display cover
4.6.5
Flange and drain vent
The Rosemount 3051SMV is attached to the process connection flange by four bolts and
two alignment cap screws.
Procedure
1. Remove the two alignment cap screws.
Operation and Maintenance Reference Manual
October 2018 00809-0100-4803
124 Rosemount 3051S Multivariable Transmitter