28 Unidrive M SI-PROFIBUS User Guide
Issue Number: 3
The hardware version of the option module is in the format of yy.zz.
The module serial number is available as a pair of 32-bit values where Serial Number
LS (Pr S.00.004) provides the least significant 8 decimal digits, and Serial Number MS
(Pr S.00.005) provides the most significant 8 decimal digits. The reconstructed serial
number is ((S.00.005 x 100000000) + S.00.004). For example, serial number
"0001234567898765" would be stored as Pr S.00.005 = 12345 and Pr S.00.004 =
67898765.
This parameter displays the current status of the module. All possible values are shown
in the table below.
Changes to the SI-PROFIBUS configuration will not take effect until the SI-PROFIBUS
has been reset.
SI-PROFIBUS hardware version
S.00.003
Default N/A
Range 00.00 to 99.99
Access RO
Serial number LS
S.00.004
Default N/A
Range 0 to 99999999
Access RO
Serial number MS
S.00.005
Default N/A
Range 0 to 99999999
Access RO
Module status
S.00.006
Default N/A
Range 0 to 99999999
Access RO
Value Text Description
0 Initializing Module is currently initializing
1 OK Module has initialized and has found no errors.
2 Config
A configuration error has been detected in one of the
communications protocols or user program.
3Error
An error has occurred preventing the firmware or user program
running correctly.
Reset module
S.00.007
Default Off (0)
Range Off (0) or On (1)
Access RW