INNOVATION AND FLEXIBILITY
“This document is intended as a guide only. Whilst the information it contains is believed to be correct, Emtelle can take no responsibility for actions taken based on the information contained in this document. Emtelle reserves the
right to make changes to this document without notice. All sales of product are subject to Emtelle’s terms and conditions of sale only, which can be found on Emtelle’s website.
1
INNOVATION IS OUR TRADITION
DESIGNED FOR FLEXIBILITY
THE
INSTALLATION AND MAINTENANCE TRAINING MANUAL
INNOVATION AND FLEXIBILITY
Issue 7: June 2009
The Installation
And Maintenance Training Manual

Table of Contents

Questions and Answers

  • A
    Anthony Morris Jr.Aug 11, 2025
    What to do if the EMTELLE Cables and connectors compressor will not start or stops suddenly?
    • J
      Jonathon DiazAug 11, 2025
      If the compressor won't start or suddenly stops, the cause may be low fuel or oil. Refill the fuel or add oil to resolve the issue and allow the compressor to run.
  • D
    David RamirezAug 25, 2025
    What to do if there is excessive leakage from the EMTELLE Cables and connectors blowing head?
    • G
      Gregory GomezAug 25, 2025
      If there's excessive leakage from the blowing head, ensure the 'O' ring is correctly positioned and replace it if damaged. Verify that the correct fibre plates are installed in the blowing head. Remove air pressure before tightening the head bolts. If the seal is faulty, replace it, or secure PTFE tape to the primary m/d.
  • C
    Courtney AbbottAug 29, 2025
    What to do if air is OK at the EMTELLE Cables and connectors blowing head, but little or none is emerging at the far end?
    • H
      hernandezmichaelAug 29, 2025
      If air is present at the blowing head but not emerging at the far end, the route may be blocked, or open somewhere, or the m/d is micro-sized (e.g. 3/2.1mm). Inspect route access points for damage or contamination. Check for m/d damage or open connectors. Use a low capacity airflow meter.
  • M
    Matthew ClineSep 4, 2025
    Why is there no air reaching the blowing head from the EMTELLE Cables and connectors compressor?
    • S
      Sheri ShawSep 4, 2025
      If the compressor is running, but no air reaches the blowing head, check that all air levers are in the 'on' position and ensure the compressor is on a level surface. If the temperature is below 0°C, the compressor may be frozen. Thaw it out with gentle heat or take it indoors.
  • S
    Steven HaleNov 16, 2025
    Why is the EMTELLE Cables and connectors fibre unit stopping or slowing severely?
    • W
      Wanda BakerNov 16, 2025
      The fibre unit might be stopping or slowing down because the end of the m/d has been reached. Check the distance and the receiving end. Alternatively, there may be an obstruction in the m/d. Inspect the distance and check for obstructions like connectors, sharp bends, kinked assemblies or stretched products. You can also try blowing without a bead. Other potential causes include moisture in the tubing (stop the blowing head motor and maintain airflow to purge the m/d, and check the aftercooler), airflow problems (check the compressor is running), static from very dry air (switch to a compressor or use one with a reduced after-cooler zone), exceeding the vertical blowing limit (split the blow into sections and use coils to support the fibre weight), or a tube size mismatch (do not connect d...