Gammapilot M FMG60 PROFIBUS PA Commissioning
Endress+Hauser 29
The alphabetic character indicates the current measurement mode of the Gammapilot M:
L: Level
S: Switch
D: Density
C: Concentration
*: no measurement mode selected yet
The first numeric character identifies the function group:
Basic setup *0
Calibration *1
Safety settings *2
...
The second numeric character identifies the individual functions within the function group:
Basic setup *0
Today's date *01
Beam type *02
Isotope *03
Operating mode *04
...
Hereinafter, the position is always indicated in brackets after the function name. "*" (not yet
selected) is always indicated as the measurement mode, e.g. "Present date" (*01)
6 Commissioning
This chapter describes how to commission the Gammapilot M using the display and
operating module VU331 (which is located in the remote display and operating unit
FHX40). Commissioning via "FieldCare" or "Field Xpert SFX100" is performed in a similar
manner. More information on the "FieldCare" operating program and on Field Xpert
SFX100 is provided in BA00027S/04/EN and BA00060S/04/EN respectively.