Gammapilot M FMG60 PROFIBUS PA Commissioning
Endress+Hauser 33
6.4.4 "Operating mode" (*04)
Local display
Operating mode *04
Stand alone
Master
Slave
This function is used to specify in which operating mode the Gammapilot M will be used.
The operating mode can only be selected once. After this, the function is automatically
locked and can only be unlocked by resetting the Gammapilot M ("Reset" (*A3) function).
A
B
C
D
1
A0018107
A Stand alone.
Only one Gammapilot M is required for measuring ranges up to 2 m (6.6 ft)
For larger measuring ranges, any number of Gammapilot M devices can be interconnected (cascade
mode). The devices are defined by software settings as:
B Master
C Slave(s) or
D End slave
1 4 to 20 mA HART; PROFIBUS PA; FOUNDATION Fieldbus