EasyManua.ls Logo

Endress+Hauser Micropilot FMR10 - Page 51

Endress+Hauser Micropilot FMR10
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Micropilot FMR10 Operating menu
Endress+Hauser 51
Confirm distance
Navigation Setup → Confirm distance
Description Does the measured distance match the real distance? Select one of the options: - Manual
map To be selected if the range of mapping is to be defined manually in the 'Mapping end
point' parameter. A comparison between actual and indicated distance is not required in
this case. - Distance ok To be selected if the measured distance matches the actual
distance. The device performs a mapping. - Distance unknown To be selected if the actual
distance is unknown. A mapping can not be performed in this case. - Factory map To be
selected if the present mapping curve (if one exists) is to be deleted. The device returns to
the 'Confirm distance' parameter and a new mapping can be recorded.
Selection Manual map
Distance ok
Distance unknown
Factory map
Factory setting Distance unknown
Mapping end point
Navigation Setup → Mapping end point
Description This parameter defines up to which distance the new mapping is to be recorded. The
distance is measured from the reference point, i.e. from the lower edge of the mounting
flange or sensor.
User entry 0 to 12 m
Factory setting 0 m
Present mapping
Navigation Setup → Present mapping
Description Indicates up to which distance a mapping has already been recorded.
User interface 0 to 100 m