EasyManua.ls Logo

Endress+Hauser Micropilot FMR20 User Manual

Endress+Hauser Micropilot FMR20
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Products Solutions Services
Operating Instructions
Micropilot FMR20
HART
Free space radar
For bulk solids
BA02096F/00/EN/02.21
71534964
2021-08-02
01.00.zz (Device firmware)

Table of Contents

Other manuals for Endress+Hauser Micropilot FMR20

Questions and Answers:

Endress+Hauser Micropilot FMR20 Specifications

General IconGeneral
Measuring PrincipleFMCW Radar
Frequency80 GHz
Housing MaterialAluminum or Stainless Steel
Enclosure RatingIP66/IP67
TypeRadar Level Transmitter
Device TypeRadar Level Transmitter
ApplicationLiquids
Process Temperature-40 to +60 °C (-40 to +140 °F)
Process Pressure-1 to +3 bar (-14.5 to +43.5 psi)
Accuracy± 2 mm
Output Signal4-20 mA HART
CommunicationHART
ApprovalsATEX, FM, CSA, IECEx

Summary

Basic safety instructions

Requirements for personnel

Outlines qualifications for personnel involved in installation, commissioning, diagnostics, and maintenance.

Intended use

Defines application, media, permitted measurements, and clarifies incorrect use.

Operational safety

Covers safe operation, unauthorized modifications, and repair guidelines.

Incoming acceptance and product identification

Installation

Installation conditions

Covers general conditions and types of installation for the device.

Post-installation check

Lists essential checks after installation for device integrity and security.

Electrical connection

Connecting the device

Details how to connect the device for HART communication.

Post-connection check

Lists checks to perform after electrical connection for proper installation.

Operability

Commissioning and operation

Installation and function check

Emphasizes performing post-installation and post-connection checks before commissioning.

Commissioning via SmartBlue (App)

Guides through commissioning using the SmartBlue app and its requirements.

Configuring level measurement via operating software

Guides on configuring level measurement using operating software like SmartBlue.

Data access - Security

Covers software locking and access code management for data security.

Diagnostics and troubleshooting

General errors

Provides a table of common errors, possible causes, and solutions.

Error - SmartBlue operation

Lists errors related to SmartBlue operation and their solutions.

Technical data

Operating menu

Related product manuals