10 Technical data PROline Promag 50
124 Endress+Hauser
Promag W / DN 300 (remote version)
Fig. 57: Dimensions Promag W / DN
300 (remote version)
Dimensions wall-mounted housing
seePage122
DN L A B C K E
EN (DIN) / JIS
[mm]
ANSI
[inch]
[mm] [mm] [mm] [mm] [mm] [mm]
25 1" 200 286 202 84 120 94
32
200 286 202 84 120 94
40 1 1/2" 200 286 202 84 120 94
50 2" 200 286 202 84 120 94
65
200 336 227 109 180 94
80 3" 200 336 227 109 180 94
100 4" 250 336 227 109 180 94
125
250 417 267 150 260 140
150 6" 300 417 267 150 260 140
200 8" 350 472 292 180 324 156
250 10" 450 522 317 205 400 156
300 12" 500 572 342 230 460 166
The fitting length (L) is always the same, regardless of the pressure rating.