4 Wiring PROline Promag 50
52 Endress+Hauser
4.2 Connecting the measuring unit
4.2.1 Connecting the transmitter
#
Warning!
Risk of electric shock. Switch off the power supply before opening the device.
Do not install or wire the device while it is connected to the power supply. Failure to
comply with this precaution can result in irreparable damage to the electronics.
Risk of electric shock. Connect the protective conductor to the ground terminal on the
housing before the power supply is applied (not necessary if the power supply is gal-
vanically isolated).
Compare the specifications on the nameplate with the local voltage supply and fre-
quency. The national regulations governing the installation of electrical equipment
also apply.
1. Remove the cover of the connection compartment (f) from the transmitter housing.
2. Feed the power supply cable (a) and signal cables (b) through the appropriate
cable entries.
3. Connect the cables in accordance with the wiring diagram:
Wiring diagram (aluminium housing)Fig. 32
Wiring diagram (stainless steel housing) Fig. 33
Wiring diagram (wall-mount housing)Fig. 34
Terminal assignment Page 54
4. Screw the cover of the connection compartment (f) firmly onto the transmitter
housing.
Fig. 32: Connecting the transmitter (aluminium field housing). Cable cross-section: max. 2.5 mm
2
a Cable for power supply: 85…260 V AC, 20…55 V AC, 16…62 V DC
Terminal No. 1: L1 for AC, L+ for DC
Terminal No. 2: N for AC, L
for DC
b Signal cable: Terminals Nos. 20–27
Page 54
c Ground terminal for protective conductor
d Ground terminal for signal cable shield
e Service adapter for connecting service interface FXA 193 (FieldCheck, FieldTool)
f Cover of the connection compartment
g Securing clamp
b
b
c
d
a
a
– 27
– 25
– 23
– 21
2
1
+ 26
+ 24
+ 22
+ 20
L1 (L+)
N (L-)
g
f
e
F06-xxxxxxxx-04-06-xx-xx-005