10 Technical data PROline Promag 50
120 Endress+Hauser
10.2 Measuring-tube specifications
Promag W
Nominal diameter
Pressure rating Inside diameter of
measuring tube
[mm] [inch]
EN (DIN)
[bar]
ANSI
[lbs]
AWWA JIS Hard rubber Polyurethane
25 1" PN 40 Cl 150
20K
24
32
PN 40
−−
20K
32
40 1 1/2" PN 40 Cl 150
20K
38
50 2" PN 40 Cl 150
10K
50
65
PN 16
−−
10K 66 66
80 3" PN 16 Cl 150
10K 79 79
100 4" PN 16 Cl 150
10K 102 102
125
PN 16
−−
10K 127 127
150 6" PN 16 Cl 150
10K 156 156
200 8" PN 10 Cl 150
10K 204 204
250 10" PN 10 Cl 150
10K 258 258
300 12" PN 10 Cl 150
10K 309 309
350 14" PN 10 Cl 150
−−
342 342
400 16" PN 10 Cl 150
−−
392 392
450 18" PN 10 Cl 150
−−
437 437
500 20" PN 10 Cl 150
−−
492 492
600 24" PN 10 Cl 150
−−
594 594
700 28" PN 10
Class D
692 692
30"
−−
Class D
742 742
800 32" PN 10
Class D
794 794
900 36" PN 10
Class D
891 891
1000 40" PN 10
Class D
994 994
42"
−−
Class D
1043 1043
1200 48" PN 6
Class D
1197 1197
54"
−−
Class D
1339 1339
1400
PN 6
−−−
1402 1402
60"
−−
Class D
1492 1492
1600
PN 6
−−−
1600 1600
66"
−−
Class D
1638 1638
1800 72" PN 6
Class D
1786 1786
2000 78" PN 6
Class D
1989 1989