4 Wiring PROline Promag 50
48 Endress+Hauser
Fig. 29: Connecting the remote version of Promag W/P
a = cover of the connection compartment, b = cover of the sensor connection housing, c = signal cable,
d = coil current cable, n.c. = not connected, insulated cable shields
Fig. 30: Connecting the remote version of Promag H
a = cover of the connection compartment, b = cover of the sensor connection housing, c = signal cable,
d = coil current cable, n.c. = not connected, insulated cable shields
6
5
5
7
7
8
4
4
37
37
36
42
42
41
41
E1 E2
GND
E
2
1
a
c
d
b
S1
E1 E2
S2 GND
E
S
n.c. n.c.n.c.
brn
wht
grn
yel
EPD
Coil circuit
Pipe
Electrode circuit
Meas.signal
F06-5xFxxxxx-04-xx-xx-en-000
6
5
5
7
7
8
4
4
37
37
36
42
42
41
41
E1 E2
DN 40...100 DN 2...25
GND
E
2
1
a
c
d
b
S1
E1 E2
S2 GND
E
S
n.c. n.c.n.c.
brn
wht
grn
yel
EPD
Coil circuit
Pipe
Electrode circuit
Meas. signal
F06-5xHxxxxx-04-xx-xx-en-000