Lap joint flange according to
JIS B2220: 10K
PVDF
Sensor DN Fits to
flange
di G L LK M H × B
5*H**-J*********** [mm] B2220 [mm] [mm] [mm] [mm] [mm] [mm]
A0005567
2 to 8 ND 15 16 95 57 70 15 62 × 42
15 ND 15 16 95 57 70 15 62 × 42
25 (DIN) ND 25 27.2 125 57 90 19 72 × 55
Fitting length = (2 × L) + 86 mm
Surface roughness: R
a
1.6 m
The requisite ground rings can be ordered as accessories
(Order No. DK5HR-****).
External thread according to
ISO 228/DIN 2999
1.4404 (316L)
Sensor DN Fits to
internal
thread
di G L S H × B
5*H**-K*********** [mm] [inch] [mm] [inch] [mm] [mm] [mm]
A0005563
2 to 8 R ³"10³" 40 10.1 62 × 42
15 R ½" 16 ½" 40 13.2 62 × 42
25
(1" ANSI)
R 1" 25 1" 42 16.5 72 × 55
Fitting length = (2 × L) + 86 mm
Surface roughness: R
a
1.6 m
Internal thread according to
ISO 228/DIN 2999
1.4404 (316L)
Sensor
DN
Fits to
external
thread
di G D L S H × B
5*H**-L*********** [mm] [inch] [mm] [inch] [mm] [mm] [mm] [mm]
A0005565
2 to 8 Rp ³"9³" 22 45 13 62 × 42
15 Rp ½" 16 ½" 27 45 14 62 × 42
25
(1" ANSI)
Rp 1" 27.2 1" 40 51 17 72 × 55
Fitting length = (2 × L) + 86 mm
Surface roughness: R
a
1.6 m
G
di
LK
L
H × B
M
G
di
L
H × B
S
D
G
di
L
H × B
S