Proline Promag W 500
40 Endress+Hauser
A0029279
16 Connection example for double pulse output (passive)
1 Automation system with double pulse input (e.g. PLC)
2 Power supply
3 Transmitter: Observe input values → 17
4 Double pulse output
5 Double pulse output (slave), phase-shifted
Relay output
A0028760
17 Connection example for relay output (passive)
1 Automation system with relay input (e.g. PLC)
2 Power supply
3 Transmitter: Observe input values → 18
Current input
A0028915
18 Connection example for 4 to 20 mA current input
1 Power supply
2 Terminal box
3 External measuring device (for reading in pressure or temperature, for instance)
4 Transmitter