Proline Promag W 500
94 Endress+Hauser
External WLAN antenna
• Antenna: ASA plastic (acrylic ester-styrene-acrylonitrile) and nickel-plated brass
• Adapter: Stainless steel and nickel-plated brass
• Cable: Polyethylene
• Plug: Nickel-plated brass
• Angle bracket: Stainless steel
Ground disks
• Stainless steel, 1.4435 (316L)
• Alloy C22, 2.4602 (UNS N06022)
• Tantalum
Fitted electrodes
Measurement, reference and empty pipe detection electrodes available as standard with:
• 1.4435 (316L)
• Alloy C22, 2.4602 (UNS N06022)
• Tantalum
Process connections
• EN 1092-1 (DIN 2501)
3)
– DN ≤ 300: fixed flange (PN 10/16/25/40) = form A
– DN ≥ 350: fixed flange (PN 6/10/16/25) = flat face
– DN 450 to 2000
4)
: fixed flange (PN 6/10/16) = flat face
• ASME B16.5
– DN 25 to 600 (1 to 24"): fixed flange (Class 150)
– DN 350 to 2000 (14 to 78")
4)
: fixed flange (Class 150)
– DN 25 to 150 (1 to 6"): fixed flange (Class 300)
• AWWA C207
– DN 48 to 72": fixed flange (Class D)
– DN 48 to 78"
4)
: fixed flange (Class D)
• AS 2129
– DN 50 to 1200: fixed flange (Table E)
– DN 350 to 1200
4)
: fixed flange (Table E)
• AS 4087
– DN 50 to 1200): fixed flange (PN 16)
– DN 350 to 1200
4)
: fixed flange (PN 16)
• JIS B2220
– DN 50 to 750: fixed flange (10K)
– DN 25 to 600: fixed flange (20K)
For information on the different materials used in the process connections
Surface roughness
Electrodes with 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum:
≤ 0.3 to 0.5 µm (11.8 to 19.7 µin)
(All data relate to parts in contact with fluid)
Operability
Operating concept
Operator-oriented menu structure for user-specific tasks
• Commissioning
• Operation
• Diagnostics
• Expert level
Fast and safe commissioning
• Guided menus ("Make-it-run" wizards) for applications
• Menu guidance with brief descriptions of the individual parameter functions
• Device access via Web server or SmartBlue app → 112
• WLAN access to the device via mobile handheld terminal, tablet or smart phone
3) Dimensions as per DIN 2501, DN 65 (2 ½") PN 16 and DN 600 (24") PN 16 only as per EN 1092-1
4) Order code for "Design", option A "Insertion length short"