Proline Promag W 500
94 Endress+Hauser
External WLAN antenna
Antenna: ASA plastic (acrylic ester-styrene-acrylonitrile) and nickel-plated brass
Adapter: Stainless steel and nickel-plated brass
Cable: Polyethylene
Plug: Nickel-plated brass
Angle bracket: Stainless steel
Ground disks
Stainless steel, 1.4435 (316L)
Alloy C22, 2.4602 (UNS N06022)
Tantalum
Fitted electrodes
Measurement, reference and empty pipe detection electrodes available as standard with:
1.4435 (316L)
Alloy C22, 2.4602 (UNS N06022)
Tantalum
Process connections
EN 1092-1 (DIN 2501)
3)
DN ≤ 300: fixed flange (PN 10/16/25/40) = form A
DN ≥ 350: fixed flange (PN 6/10/16/25) = flat face
DN 450 to 2000
4)
: fixed flange (PN 6/10/16) = flat face
ASME B16.5
DN 25 to 600 (1 to 24"): fixed flange (Class 150)
DN 350 to 2000 (14 to 78")
4)
: fixed flange (Class 150)
DN 25 to 150 (1 to 6"): fixed flange (Class 300)
AWWA C207
DN 48 to 72": fixed flange (Class D)
DN 48 to 78"
4)
: fixed flange (Class D)
AS 2129
DN 50 to 1200: fixed flange (Table E)
DN 350 to 1200
4)
: fixed flange (Table E)
AS 4087
DN 50 to 1200): fixed flange (PN 16)
DN 350 to 1200
4)
: fixed flange (PN 16)
JIS B2220
DN 50 to 750: fixed flange (10K)
DN 25 to 600: fixed flange (20K)
For information on the different materials used in the process connections
Surface roughness
Electrodes with 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum:
≤ 0.3 to 0.5 µm (11.8 to 19.7 µin)
(All data relate to parts in contact with fluid)
Operability
Operating concept
Operator-oriented menu structure for user-specific tasks
Commissioning
Operation
Diagnostics
Expert level
Fast and safe commissioning
Guided menus ("Make-it-run" wizards) for applications
Menu guidance with brief descriptions of the individual parameter functions
Device access via Web server or SmartBlue app →  112
WLAN access to the device via mobile handheld terminal, tablet or smart phone
3) Dimensions as per DIN 2501, DN 65 (2 ½") PN 16 and DN 600 (24") PN 16 only as per EN 1092-1