Proline Promag W 500
Endress+Hauser 51
Mounting the transmitter
housing
Post mounting
1
4 x
SW 13
! (! 0.79 to 2.75)20 70
A0029057
 29 Engineering unit mm (in)
Wall mounting
20 (0.79)
100 (3.94)
100 (3.94)
! 8.6 (0.39)
! 18 (0.71)
! 10 (0.39)
A0029068
 30 Engineering unit mm (in)
Special mounting
instructions
Permanent immersion in water
A fully welded remote version with IP68 protection is optionally available for permanent immersion
in water ≤ 3 m (10 ft) or in exceptional cases for use for up to 48 hours at ≤ 10 m (30 ft). The
measuring device meets the requirements of corrosion categories C5-M and Im1/Im2/Im3. The fully
welded design along with the connection compartment sealing system ensure that moisture cannot
enter the measuring device.