Installation Proline Promag W 800
14 Endress+Hauser
6 Installation
6.1 Installation conditions
No special measures such as supports are necessary. External forces are absorbed by the
construction of the device.
6.1.1 Mounting position
Mounting location
Preferably install the sensor in an ascending pipe,
and ensure a sufficient distance (2 × DN) to the next pipe elbow.
A0017061
Fig. 4: Selecting the mounting location
To prevent measuring errors from gas bubbles accumulating in the measuring tube, avoid the
following mounting locations in the pipe:
Highest point of a pipeline
Directly upstream of a free pipe outlet in a down pipe
h