Proline Promag W 800 Installation
Endress+Hauser 27
Pipe mounting
The assembly should be performed by following the instructions in the graphic.
"
Caution!
If using a warm pipe, make sure that temperatures do not exceed the permitted ambient
temperature range .
A0016412
Fig. 16: Pipe mounting (wall-mount housing)
6.3 Post-installation check
ø 20…70
( 0.79…2.75)
ø
mm (in)
PH 2
SW 8
4 x
4 x
~ ~ 6.7)170 (
Is the measuring device undamaged (visual inspection)?
Does the measuring device meet the specifications of the measuring point?
For example, process temperature, process pressure, ambient temperature, measuring range etc.
Has the correct orientation been selected for the sensor 14?
According to sensor type
According to fluid temperature
According to fluid properties (outgassing, with entrained solids)
Does the arrow on the sensor nameplate match the actual direction of fluid flow through the pipe?
Are the measuring point identification and labeling correct (visual inspection)?
Is the device adequately protected from precipitation and direct sunlight?
Have the fastening elements been tightened with the correct tightening torque?