System integration Proline Promass I 300 PROFINET
78 Endress+Hauser
Selection: input variable
Slot Input variables
1 to 14
Mass flow
Volume flow
Corrected volume flow
Density
Reference density
Temperature
Electronic temperature
Oscillation frequency
Frequency fluctuation
Oscillation damping
Tube damping fluctuation
Signal asymmetry
Exciter current
Application-specific output 0
Application-specific output 1
Index inhomogeneous medium
Index suspended bubbles
24 to 26 Current input value
1 to 14
Additional input variables with the Heartbeat Verification application package
Carrier pipe temperature
Oscillation damping 1
Oscillation frequency 1
Oscillation amplitude 0
Oscillation amplitude 1
Frequency fluctuation 1
Tube damping fluctuation 1
Exciter current 1
HBSI
1 to 14, 27
Additional input variables with the Concentration Measurement application
package
Concentration (slot 1 to 14)
Target mass flow (slot 1 to 14)
Carrier mass flow (slot 1 to 14)
Concentration value (slot 27)
1 to 14
Additional input variables with the Petroleum application package
Oil density
Water density
Water cut %
Oil mass flow
Water mass flow
Oil volume flow
Water volume flow
Oil corrected volume flow
Water corrected volume flow
Replacement reference density
Gross corrected volume flow
Gross corrected volume flow, replacement
Net corrected volume flow
Net corrected volume flow, replacement
Sediment and water volume flow
1 to 14
Additional input variables with the Viscosity Measurement application
package
Dynamic viscosity
Kinematic viscosity
Temp. compensated dynamic viscosity
Temp. compensated kinematic viscosity