Proline Prosonic Flow P 500
Endress+Hauser 7
Sensor
Prosonic Flow P
• Measurement of:
• Pure liquids or slightly contaminated liquids
• Chemicals
• Solvents
• Liquid hydrocarbons
• Acids
• Alkalis
• Nominal diameter range: DN 15 to 4000 (½ to 160")
• Materials:
• Sensor holder:
Stainless steel 1.4301 (304), 1.4404 (316L)
• Sensor housing:
Stainless steel 1.4301 (304), 1.4404 (316L)
• Strapping band/bracket:
Stainless steel 1.4301 (304), 1.4404 (316L)
• Sensor contact surface:
Chemically stable plastic
Stainless steel 1.4404 (316L)
DN 15 to 65 (½ to 2½")
A0011484
DN 50 to 4000 (2 to 160")
A0013475
1 Example: 1 sensor set with 2 traverses
DN 50 to 4000 (2 to 160")
A0053234
2 Example: high-temperature sensors
comprising 1 sensor set with
1 traverse
DN 50 to 600 (2 to 24")
A0051732
3 Example: high-temperature sensors
comprising 2 sensor sets with 1
traverse
Accessories for mounting
The required distances must be determined for the sensors. Information about the medium, the pipe
material used and the exact pipe dimensions is necessary to determine these values. The values for
the sound velocity of the following media, pipe materials and liner materials are saved in the
transmitter.
Order code for "Sensor version", options AG, AH: high-temperature sensors may only be
installed on metallic pipes.