Proline Prosonic Flow P 500
Endress+Hauser 43
1
10 × DN
3× DN
4
a
b
C
A
B
D
6
5
15 × DN
15 × DN
20 × DN
20 × DN
3
0…15 × DN
0…15 × DN
2
15 × DN
A0053303
34
A Inlet and outlet runs DN 50 to 4000 (2 to 160")
B Inlet and outlet runs DN 15 to 65 (½ to 2½")
C Inlet and outlet runs for high-temperature sensors
D Position of inlet and outlet runs on sensor
1 Pipe elbow 90° or 45°
2 Two pipe elbows 90° or 45° (in one plane, with 0 to 15 x DN between the elbows)
3 Two pipe elbows 90° or 45° (in two planes, with 0 to 15 x DN between the elbows)
4a Reduction
4b Extension
5 Control valve (2/3 open)
6 Pump
Mounting the sensor
L
WARNING
Risk of injury when mounting sensors and strapping bands!
‣
Suitable gloves and goggles must be worn due to the increased risk of cuts.
L
DANGER
Risk of burns from hot surfaces!
‣
Wear suitable protective equipment such as temperature-resistant protective gloves, clothing or
protective visors.
‣
Before commencing work: allow the system and measuring device to cool to a touch-safe
temperature.
High-temperature applications (> 170°C)
• Order code for "Process temperature", options H, I, J
• Installation for high-temperature applications may only be performed by Endress+Hauser
staff or by individuals authorized and trained by Endress+Hauser.