EasyManua.ls Logo

Endress+Hauser Proline Prosonic Flow P 500 - Mounting the Sensor

Endress+Hauser Proline Prosonic Flow P 500
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Prosonic Flow P 500
Endress+Hauser 43
1
10 × DN
3× DN
4
a
b
C
A
B
D
6
5
15 × DN
15 × DN
20 × DN
20 × DN
3
0…15 × DN
0…15 × DN
2
15 × DN
A0053303
 34
A Inlet and outlet runs DN 50 to 4000 (2 to 160")
B Inlet and outlet runs DN 15 to 65 (½ to 2½")
C Inlet and outlet runs for high-temperature sensors
D Position of inlet and outlet runs on sensor
1 Pipe elbow 90° or 45°
2 Two pipe elbows 90° or 45° (in one plane, with 0 to 15 x DN between the elbows)
3 Two pipe elbows 90° or 45° (in two planes, with 0 to 15 x DN between the elbows)
4a Reduction
4b Extension
5 Control valve (2/3 open)
6 Pump
Mounting the sensor
L
WARNING
Risk of injury when mounting sensors and strapping bands!
Suitable gloves and goggles must be worn due to the increased risk of cuts.
L
DANGER
Risk of burns from hot surfaces!
Wear suitable protective equipment such as temperature-resistant protective gloves, clothing or
protective visors.
Before commencing work: allow the system and measuring device to cool to a touch-safe
temperature.
High-temperature applications (> 170°C)
Order code for "Process temperature", options H, I, J
Installation for high-temperature applications may only be performed by Endress+Hauser
staff or by individuals authorized and trained by Endress+Hauser.