EasyManua.ls Logo

Endress+Hauser Proline Prosonic Flow P 500 - Display and User Interface; Operation Concept

Endress+Hauser Proline Prosonic Flow P 500
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Prosonic Flow P 500
72 Endress+Hauser
Coupling pads
–40 to +100 °C (–40 to +212 °F): silicon-based thermal pad H48.2 (0.5 mm (0.02 in))
–40 to +170 °C (–40 to +338 °F): VMQ-silicone-rubber (vinyl methyl silicone) (0.5 mm (0.02 in))
Coupling foil
150 to 220 °C (302 to 428 °F): tin
210 to 370 °C (410 to 698 °F): zinc
350 to 550 °C (662 to 1 022 °F): aluminum
Coupling paste
Coupling grease
Accessories
Protective cover
Stainless steel, 1.4404 (316L)
External WLAN antenna
Antenna: ASA plastic (acrylonitrile styrene acrylate) and nickel-plated brass
Adapter: Stainless steel and nickel-plated brass
Cable: Polyethylene
Plug: Nickel-plated brass
Angle bracket: Stainless steel
Display and user interface
Operation concept
Operator-oriented menu structure for user-specific tasks
Commissioning
Operation
Diagnosis
Expert level
Quick and safe commissioning
Guided menus ("Make-it-run" wizards) for applications
Menu guidance with brief descriptions of the individual parameter functions
Access to the device via web server
WLAN access to the device via mobile handheld terminal, tablet or smart phone
Reliable operation
Operation in local language
Uniform operating philosophy applied to device and operating tools
If replacing electronic modules, transfer the device configuration via the integrated memory
(HistoROM backup) which contains the process and measuring device data and the event logbook.
No need to reconfigure.
Efficient diagnostics increase measurement reliability
Troubleshooting measures can be called up via the device and in the operating tools
Diverse simulation options, logbook for events that occur and optional line recorder functions
Installation quality
To optimize the sensor mounting positions, real-time display of:
Installation status (good, bad, acceptable)
Signal strength
Signal to noise ratio
Sound velocity

Table of Contents

Other manuals for Endress+Hauser Proline Prosonic Flow P 500

Related product manuals