Proline Prosonic Flow P 500
80 Endress+Hauser
Ex ec
Transmitter Sensor
Category Type of protection Category Type of protection
II3G Ex ec ic IIC
II3G Ex ec nC IIC T5…T4 Gc II3G Ex ec ic IIC
Ex tb
Transmitter Sensor
Category Type of protection Category Type of protection
II2D Ex ia tb IIIC T** °C Db
C
CSA
US
Currently, the following versions for use in hazardous areas are available:
IS
Transmitter Sensor
Class I Division 2 Groups A - D Class I, II, III Division 1 Groups A-G
NI
Transmitter Sensor
Class I Division 2 Groups A - D Class I Division 2 Groups A - D
Ex i
Transmitter Sensor
Class I Zone 2, AEx/Ex nA nC IIC T5…T4 Gc Class I Zone 1, AEx/Ex d ia IIC T6…T1 Gb
Ex nA
Transmitter Sensor
Class I Zone 2, AEx/Ex nA nC IIC T5…T4 Gc Class I Zone 2, AEx/Ex nA ic IIC T6…T1 Gc
Ex tb
Transmitter Sensor
Zone 21, AEx/Ex ia tb IIIC T** °C Db
Functional safety
The measuring device can be used for flow monitoring systems (min., max., range) up to SIL 2
(single-channel architecture; order code for "Additional approval", option LA) and SIL 3 (multi-
channel architecture with homogeneous redundancy) and is independently evaluated and certified in
accordance with IEC 61508.
The following types of monitoring in safety equipment are possible:
Volume flow