Mounting the transmitter
housing
Proline 500 transmitter
Pipe mounting
Required tools
Open-ended wrench AF 13
L
WARNING
Order code for "Transmitter housing", option L "Cast, stainless": cast transmitters are very
heavy.
They are unstable if they are not mounted on a secure, fixed post.
Only mount the transmitter on a secure, fixed post on a stable surface.
1
4 x
SW 13
! (! 0.79 to 2.75)20 70
A0029057
 54 Engineering unit mm (in)
Wall mounting
Required tools
Drill with drill bit ⌀ 6.0 mm
20 (0.79)
100 (3.94)
100 (3.94)
! 8.6 (0.39)
! 18 (0.71)
! 10 (0.39)
A0029068
 55 Engineering unit mm (in)