Connecting High-Speed Stacking Cables
3-10 Hardware Installation
3. Ifyouareinstallingthisswitchinastackedconfiguration,repeatthisprocedurefor
eachswitchuntilallswitcheshavebeeninstalledinthestack,thenproceedto
ConnectingHighSpeedStackingCablesonpage 310.Otherwise,proceed to
ConnectingACandPoEPoweronpage 314.
Connecting High-Speed Stacking Cables
Thestackofswitchescanbeconnectedinaringordaisychaintopology.Inaring
topologyalltheswitchesareconnected.Theonlydifferenceinthecableconnectionsina
daisychaintopologyisthatonecableisnotinstalled.
Upto8switchescanbestackedtogetherusing
C2CABSHORTandC2CABLONG
highspeedstackingcables.Youcanaddswitchesandreachuptoamaximumof384
Ethernetportsperstack.Thehighspeedstackingcablesallowtheentirestacktooperate
withasingleIPaddress.
Figure 39showsanexampleofafourhighstack
connectedinaringtopology.AllSTACK
DOWNandSTACK UPconnectorsareusedintheinstallation.Thehighspeedstacking
cable(1)
connectionsarefromtheSTACKDOWNconnector(2)ofoneswitchtothe
STACKUP(3)
connectorofthenextswitchupinthestack.Ahighspeedstackingcable
connectionfromtheSTACKDOWN(4)
connectoroftheswitchatthetopofthestackto
theSTACKUP(5)
connectoratthebottomof thestackcompletestheringconnection.Ina
daisychaintopology,thelastcableconnectionisnotmade.
Thehighspeedstackingcablesareoptionalitemsandmustbeordered
separately.TheB2G12448Pand B2H12448PsupportthreetypesofSecureStack
stackingcables:
•C2CABSHORTcable
toconnecttwoadjacentswitchesinthestack.Ifthe
stackisinaconfigurationwheretheadjacentswitchesaretoofarapartfor
theSHORTcables,theLONGcablecanbeusedfortheconnections.
•C2CABLONGcabletoconnectfromthetopswitchtothebottomswitchin
the
stack.YouneedonlyoneC2CABLONGcableperstack.
•C2CAB5Mcabletoconnectfromthetopswitchtothebottomswitchinthe
stackwhenthesetwoswitchesarephysicallylocatedinseperatemounting
racksandrequirealongercablereach.