Troubleshooting Checklist
SecureStack B2 Installation Guide 4-7
Troubleshooting Checklist
Ifthedeviceisnotworkingproperly,refertoTable 4‐5forachecklistofproblems,
possiblecauses,andrecommendedactionstoresolvetheproblem.
B2H124-48P ONLY
Link/
Activity
(MGBIC 
ports 49–52)
Off 1. No link.
2. No activity or port in standby. 
None.
None.
Green Solid. Port is linked, but the interface is not 
receiving any traffic.
None.
Blinking. Port is linked and traffic is being 
received or transmitted by the interface.
None.
Table 4-4 LANVIEW LED Diagnostic Indications (continued)
LED Color State Recommended Action
Table 4-5 Troubleshooting Checklist 
Problem Possible Cause Recommended Action
All LEDs are OFF. Loss of power. Ensure that the switch was installed properly according to 
the installation instructions in Chapter 3.
Ensure that the power cords are connected properly to an 
active power source that meets the AC input specifications 
for this switch.
Ensure that the AC power cord is not damaged. Replace 
the power cord with a known good one.
No local 
management 
startup screen.
Incorrect terminal setup. Refer to the SecureStack B2 Configuration Guide for proper 
setup procedures.
Improper Console cable 
pinouts.
Refer to Appendix A for proper Console port pinouts.
Corrupt firmware image, or 
hardware fault.
If possible, attempt to download the image to the device 
again. Refer to the SecureStack B2 Configuration Guide for 
details.
Cannot navigate 
beyond startup 
screen.
Improper Community Names 
Table.
Refer to the SecureStack B2 Configuration Guide for the 
Community Names Table setup.