Connecting AC and PoE Power
3-16 Hardware Installation
C2RPS-PoE Redundant Power System
IfyouareconnectinganoptionalPoEredundantpowersupply(C2RPSPOE),refertothe
installationinstructionssuppliedwiththeSecureStackC2RPSPOE.Theswitchis
connectedtoaC2RPSPOEusingaC2RPSPOECable.
Ifyouareinstallingtheswitchasastandalonedevice,proceedtoConnectingtoConsole
PortforLocalManagementonpage 317.Ifyouareinstallingswitchesinastack
configuration,proceedtoStackInitializationOverviewonpage 316.
Stack Initialization Overview
Whenyouinstallandconnectallthehighspeedstackingcablestotheswitchesinthe
stackbeforeapplyingpowertotheswitches,thefollowingoccurs:
•Theswitchthatwillmanage(Manager)thestackisautomaticallyestablishedwithall
otherswitchesestablishedasMemberswitchesinthestack.Whentheswitches
completetheirinitializations,oneoftheswitchesinthestackwillilluminateits
ManagerLED,indicatingthatitisthestackManager.TheManagerLEDoneach
Memberswitchwillbeoff.
•ThehierarchyoftheswitchesthatwillfunctionasbackupManagerisalsodetermined
incasethecurrentManager
malfunctions,ispowereddown,orisdisconnectedfrom
thestack.
•TheConsoleportoneachMemberswitchisdeactivated.OnlytheConsoleportonthe
ManagerswitchisactiveforoutofbandconfigurationtosettheIPaddress,
password,andotherconfigurationsettings.
OnceyouknowwhichswitchistheManager,
proceedtoConnectingtoConsolePortfor
LocalManagementonpage 317.
Caution: The C2RPS-POE power supply does not support non-PoE compliant
SecureStack C2 switches. Do not try to connect the power cable from this C2RPS-POE
power supply to any SecureStack C2 switch that does not have a “P” suffix in the model
name. (Example: C2G124-24.) Otherwise, damage to the device may result.
Precaución: La fuente de poder C2RPS-POE no es compatible con switches
SecureStack C2 que no cumplan con el estándar PoE. No intente conectar el cable de
corriente de esta fuente de poder C2RPS-POE a ningún switch SecureStack C2 que no
tenga el sufijo “P” en el nombre del modelo. (Ejemplo: C2G124-24.) De lo contrario, el
dispositivo puede dañarse.