Installing the Switch on a Flat Surface
3-8 Hardware Installation
Guidelines for Installation
Locatetheswitchwithin152cm(5ft.)ofitspowersourceandonasurfaceasshownin
Figure 34.Ifanoptionalredundantpowersystemisgoingtobeinstalledandconnected
tothe14pinRedundantPowerSupplyinputconnectorontherearoftheswitch,
referto
theinstallationguideshippedwiththeredundantpowersystem.
Ifyouareinstallingseveralswitchesinastack,proceedtoConnectingHighSpeed
StackingCablesonpage 311.Iftheswitchisbeinginstalledasastandaloneswitch,
proceedtoConnectingACandRPSPoweronpage 3
15forpowerconnection
instructions.
Figure 3-4 Area Guidelines for Switch Installation on Flat Surface
Caution: To ensure proper ventilation and prevent overheating, leave a minimum
clearance space of 5.1 cm (2.0 in) at the left, right, and rear of the switch.
Do not connect the switch to the AC power source until instructed to do so later in the
installation process.
Precaución: Para asegurar una buena ventilación y evitar que el sistema
sesobrecaliente, deje un espacio mínimo de 5.1 cm (2 pulgadas) con respecto a los lados
y a la parte posterior del aparato.
1 Approximately 152 cm (5 ft.) from power source 3 44.5 cm (19.4 in.) for proper ventilation
2 4.45 cm (1.75 in.) per switch. (Vertical clearance
depends on number of switches stacked.)
4 419.0 cm (16.5 in.) for proper ventilation
À
Á
Ã
Â
Console
1
2
23
24
21 22 23 24
CPU
UP
RPS
MGR
DOWN
123456789101112 131415161718192021222324
11
12
13
14
21 22 23 24
C2G124-24

Table of Contents