Connecting AC and RPS Power
SecureStack C2 Installation Guide 3-17
RPS Power
Ifyouareinstallinganoptionalredundantpowersystem(C2RPS‐SYS),refertothe
installationinstructionssuppliedwiththeRPS.TheswitchisconnectedtoaC2RPS‐PSM
usingaC2RPS‐PSMCable.
Ifyouareinstallingtheswitchasastandalonedevice,proceedto“ConnectingtoConsole
PortforLocal
Management”onpage 3‐18.Ifyouareinstallingswitchesinastack
configuration,applypowertoeachswitchinorder,accordingtotheprocedureyouusein
“ConfiguringSwitchesinaStack”onpage 3‐12.
Stack Initialization Overview
Whenyouinstallandconnectallthehigh‐speedstackingcablestotheswitchesinthe
stackbeforeapplyingpowertotheswitches,thefollowingoccurs:
•Theswitchthatwillmanage(Manager)thestackisautomaticallyestablishedwithall
otherswitchesestablishedasMemberswitchesinthestack.Whentheswitches
completetheirinitializations,oneoftheswitchesinthestackwillilluminateits
ManagerLED,indicatingthatitisthestackManager.TheManagerLEDoneach
Memberswitchwillbeoff.
•ThehierarchyoftheswitchesthatwillfunctionasbackupManagerisalsodetermined
incasethecurrentManager
malfunctions,ispowereddown,orisdisconnectedfrom
thestack.
•TheConsoleportoneachMemberswitchisdeactivated.OnlytheConsoleportonthe
Managerswitchisactiveforout‐ofbandconfigurationtosettheIPaddress,password
andotherconfigurationsettings.
OnceyouknowwhichswitchistheManager,
proceedto“ConnectingtoConsolePortfor
LocalManagement”onpage 3‐18.
Caution: The C2G124-24, C2G124-48, and C2H124-48 are not PoE-compliant devices.
Do not connect a SecureStack C2 PoE Redundant Power Supply (C2RPS-POE) to the
DC power connector. Otherwise damage to the device may result.
Precaución: Los dispositivos C2G124-24, C2G124-48, y C2H124-48 no cumplen con el
estándar PoE (power over ethernet). No conecte una fuente de poder redundante (RPS)
SecureStack C2 PoE (C2RPS-POE) al cable de corriente. De lo contrario, el dispositivo
puede dañarse.