Installation 2. Installation
RC700 Series Rev.3 19
G6 :Ceilling Mounting
WARNING
Install the
Ceiling Mounting Manipulator with two or more people.
The Manipulator
weights are as follows. Be careful not to get hands, fingers, or
feet caught and/or have equipment damage
d by a fall of the Manipulator.
G6
-45**R : Approximately 27 kg: 60 lbs.
G6
-55**R : Approximately 27 kg: 60 lbs.
G6
-65**R : Approximately 28 kg: 62 lbs.
When installing
the Manipulator to the ceiling, support the Manipulator, and then
secure
the anchor bolts. Removing the support without securing the anchor
bolts properly
is extremely hazardous and may result in fall of the Manipulator.
(1)
Unpack the Manipulator with retaining the
arm
posture.
(2)
Secure the base to the
ceiling with four
bolts.
Use bolts
with specifications conforming to
ISO898
-1 Property Class: 10.9 or 12.9.
Tightening torque
: 32.0 N
·m (326 kgf·cm)
4-M8×4
Screw Hole
(depth 20 mm or more)
Spring Washer
Pane Washer
(3)
Remove the shipping bolt and jigs.