SC-S30600 Series Revision B
TROUBLE SHOOTING Other Troubles 58
Confidential
After Heater power failure occurs
The power cable of the After Heater is
not connected.
--- Connect the power cable of the After Heater.
It takes a longer time to warm up the
heater.
It takes 10 minutes or longer until the
heater temperature reaches the preset
level.
1. Is the heater setting appropriate in the ambient
temperature?
2. Is the thermistor detached from the plate?
See the panel display to identify which heater has not been
warmed up.
1. Make the following settings.
Raise the ambient temperature.
Turn the heater temperature setting down.
2. Screw the thermistor on the plate.
The Drying Fan does not work when
printing.
The power cable of the Drying Fan Unit
is not connected.
Does the Drying Fan icon appear on the panel display? Connect the power cable of the Drying Fan Unit.
The Drying Fan Unit is not connected
to the printer.
Does the Drying Fan icon appear on the panel display? Connect the Drying Fan Unit to the printer.
The Drying Fan function has been
disabled with the panel setting.
Does the Drying Fan icon (ON) appear on the panel
display?
Enable (select “ON”) the Drying Fan function.
Table 2-4. Other Troubles
Symptom Cause Check Item Remedy