Maintenance 3. Covers
G6 Rev.21 105
3.8 Base Bottom Cover
The base bottom cover is removed only when replacing the gasket unit.
Unscrew the base bottom cover mounting bolts and remove the cover.
G6-***C* (Cleanroom-model)
G6-***D*, P* (Protected-model)
Table Top
mounting
6-M3×8
6-M3×8
Gasket
Ceiling
mounting
6-M3×8
6-M3×8
Gasket
A gasket is installed to G6-***D*, P* (Protected-model).
A base bottom cover is not installed to G6-***S* (Standard-model).