EPSON Stylus Photo 925 Revision A
Disassembly and Assembly Disassembly 116
4. With the characters-readable side down, stick the PF Scale on the Scale Mounting
Plate.
Figure 4-92. Sticking the PF Scale
5. Peel the backing paper off the D50 tape and stick the tape on the PF Scale.
Figure 4-93. Sticking the D50 Tape
6. Peel the protective backing off the D50 Tape stuck on the PF Scale.
C A U T I O N
T Do not touch the following surfaces:
• Inside of the mounting hole for PF Roller Shaft of the PF Scale
• Printed side of the PF Scale
T The Scale Mounting Plate does not have to be positioned so that
its contour is adjusted to the circle printed on the PF Scale.
With this side down
PF Scale
Mounting Plate Scale
Mounting plate scale tool No. 1051765
C A U T I O N
The D50 Tape does not have to be positioned so that its contour is
adjusted to the circle printed on the PF Scale.
D50 Tape
Protective backing
PF Scale
Protective backing
Mounting plate scale tool No.1051765