EPSON Stylus Pro 7400/7800/9400/9800 Revision B
Product Description Control Panel 121
Ink-mark Sensor Position Adjustment
The position of the Ink-mark sensor can be adjusted and checking the sensor for
detecting ability can be made.
Figure 1-38.
Ink-mark Sensor Position Adjustment Pattern
Figure 1-39. Ink-mark Sensor Operation Check Pattern
4251 Approx. 300 12755 Approx. 900
5669 Approx. 400 14173 Approx. 1000
7086 Approx. 500 --- ---
Table 1-62. Positions of Printed Lines
360dpi-based
Intervals
On a millimeter
basis
360dpi-based
Intervals
On a millimeter
basis
[PG=1.2]
Multi-Sensor Position Adjust PG0.8mm PG1.2mm PG2.1mm PG2.6mm
Horizontal [mm] : -1.3 -1.3 0.0 0.0
Vertical [mm] : 0.4 0.4 0.0 0.0
Print mode: 360dpi, Bi-D, 320cps, VSD1, Large
[PG=1.2]
[Count] MK:5 C :5 M :5 Y :5 LLk:5 Lm:5 LC:5 Lk:5
[Position] MK : ( 1, 3), ( 9, 3), ( 5, 13), ( 1, 22), ( 9, 22), ( 0, 0),
( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0)
[Position] C : ( 1, 3), ( 9, 3), ( 5, 13), ( 1, 22), ( 9, 22), ( 0, 0),
( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0)
[Position] M : ( 1, 3), ( 9, 3), ( 5, 13), ( 1, 22), ( 9, 22), ( 0, 0),
( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0)
[Position] Y : ( 1, 3), ( 9, 3), ( 5, 13), ( 1, 22), ( 9, 22), ( 0, 0),
( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0)
[Position] LLk : ( 1, 3), ( 9, 3), ( 5, 13), ( 1, 22), ( 9, 22), ( 0, 0),
( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0)
[Position] Lm : ( 1, 3), ( 9, 3), ( 5, 13), ( 1, 22), ( 9, 22), ( 0, 0),
( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0)
[Position] Lc : ( 1, 3), ( 9, 3), ( 5, 13), ( 1, 22), ( 9, 22), ( 0, 0),
( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0)
[Position] Lk : ( 1, 3), ( 9, 3), ( 5, 13), ( 1, 22), ( 9, 22), ( 0, 0),
( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0), ( 0, 0)
Print mode: 360dpi, Bi-D, 320cps, VSD1, Large