EasyManua.ls Logo

Epson STYLUS PRO 9400 - Rear Sensor Adjustment

Epson STYLUS PRO 9400
428 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus Pro 7400/7800/9400/9800 Revision B
Adjustment Basic Adjustment 340
5.3.21 Rear Sensor Adjustment
Whenever the Rear Sensor is replaced, AD values (basis for paper detection) of a
newly attached sensor should be obtained to store them onto the Main Board.
Required Tool
Kimoto, Micro Trace #300
Procedure
1. Enter into the Serviceman Mode.
Turn the printer ON while holding down the [Paper Source ], [Menu
], and [Paper Feed ].
2. Select “SELF TESTING: Adjustment” to enter the Self Testing menu.
[Paper Feed ] [Menu ]
3. Select “Adjustment: RearAD”.
[Paper Feed ] five times
4. Release the Paper Set Lever.
5. Load the Micro Trace on the printer from the rear paper feeder setting it to the
position shown in Figure 5-63, and lower the Paper Set Lever.
6. Press the [Menu ] button. “[Enter] Start” will be displayed on the LCD
panel.
7. Press the [Enter ] button to start the AD value acquisition operation. After
about five seconds, the obtained AD value is displayed as “RearAD: *** ***
***”.
8. After confirming the “RearAD: *** *** ***” display, release the Paper Set
Lever and remove the Micro Trace.
9. Lower the Paper Set Lever and turn the printer OFF.
Figure 5-63. Setting the Micro Trace
C A U T I O N
In Figure 5-63, the H Top Cover is removed to show the position of
the Micro Trace clearly. When performing the adjustment, do not
remove the H Top Cover, or the AD value cannot be obtained
correctly.
C A U T I O N
“Retry AD Adjust” is displayed when the value cannot be obtained
due to Rear Sensor failure. In such case, replace the sensor and
make the adjustment again.
Micro Trace