EasyManua.ls Logo

Epson STYLUS PRO 9400 - Cr Hp Sensor

Epson STYLUS PRO 9400
428 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus Pro 7400/7800/9400/9800 Revision B
Disassembly & Assembly Disassembly Procedure 244
4.2.5.3 CR HP Sensor
1. Remove the MAIN TUBE HOLDER. See Section 4.2.5.1 on page 240.
2. Pull out the MAIN TUBE HOLDER frontward, and release the three hooked tabs
that secure the CR HP Sensor and remove the sensor.
3. Disconnect the connector from the CR HP Sensor.
Figure 4-61. Removing the CR HP Sensor
C A U T I O N
When performing the next step, be careful not to pull out the MAIN
TUBE HOLDER forcibly as TUBE, SUPPLY, INKs are routed
inside the holder.
Figure 4-60. Handling the MAIN TUBE HOLDER
TUBE, SUPPLY, INK
Hooked Tabs
CR HP Sensor
Connector

Table of Contents

Other manuals for Epson STYLUS PRO 9400

Related product manuals