Front Panel Control
User Authentication
Enable
On, Off. Determines whether authentication is required for controlling
the unit.
User Name
The user name used for authentication if user authentication is
enabled.
Password
The password used for authentication if user authentication is
enabled.
Fan Speed Information Only
Fans Speed Control
Lowest Noise, Quiet, Cool or Best Cooling. Sets the fan speed to
achieve the required operation whilst maintaining a safe operating
temperature within the unit.
Fans Speed Status Lists the speed of the respective fans in rpm.
Fan 1
Fan 2
Fan 3
Fan 4
Fan 5
Voltage Rails Status
Lists the actual voltage or current levels of the respective nominal
outputs.
0.9V A
0.9V B
1.0V
1.0V GTP
1.2V GTP
1.2V
1.5V
1.8V
2.5V
2.5V Vcc Aux
3.0V
3.3V
3.6V
Front Panel Parameters
LED Brightness Control 0-7. The brightness of the keys and the rotary knob.
Video Monitor Preview Time
The time in seconds after which the TND is to be turned off
automatically. If 0 is given as value, the TND does not turn out
automatically.