EasyManua.ls Logo

Ericsson AVP 2000 Series - Alarms List - CE-Xa VCM; CE-Xa Pre-Processor Module

Ericsson AVP 2000 Series
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm Lists
EN/LZT 790 0023/1 R16A
E-25
Alarm Description Port Number Alarm ID Source Severity
Audio 4 Dolby E metadata frame
rate mismatch
Frame rate indicated in Dolby E
metadata does not match current
video frame rate.
0 010C2067 Audio 4 minor
Audio 4 ADS control track
Control track for audio description
not present.
0 010C2068 Audio 4 minor
Audio 4 ADS silence
Silent period detected. Valid only for
Audio Description Service encoding.
0 010C2069 Audio 4 minor
Audio 4 Clipping
Audio output is clipping. Audio gain
value or input amplitude should be
reduced.
0 010C206A Audio 4 minor
E.4 Alarms List – CE-xA VCM
The following table lists the alarm and failure identifiers generated by the CE-xA
VCM.
E.4.1 CE-xA Pre-Processor Module
Table E.4 Alarm List CE-xA VCM (CE-x Pre-Processor Module)
Alarm Description Port Number Alarm ID Source Severity
Over Temperature Warning
Failure to take action may cause
permanent damage to the unit.
Please check the fans are working
correctly, and that the ambient
temperature is not excessive.
0 010C0000
CE-x
Analogue
Module
minor
Over Temperature
Failure to take action may cause
permanent damage to the unit.
Please switch off and refer to
Customer Support.
0 010C0001
CE-x
Analogue
Module
critical
Invalid Parameter
Invalid Parameter received by the
Video/Audio Module. Please see
Video Encoder status for a more
detailed description of the error.
0 010C0002
CE-x
Analogue
Module
critical
Video/Audio Module Error
Video/Audio Module Error. Please
see Video Encoder status for a more
detailed description of the error.
0 010C0003
CE-x
Analogue
Module
critical
Power On Self Test Failure
At least one start-up test has failed.
Problems may be experienced with
the normal operation of the unit.
0 010C0004
CE-x
Analogue
Module
critical
Invalid Configuration
An invalid configuration has been
applied. Check Video Standard and
Profile selection.
0 010C0006
CE-x
Analogue
Module
minor
Option Card Build Version
Mismatch
The software on this option card is
not an officially released version.
0 010C0007
CE-x
Analogue
Module
minor
Video Processor Error
An error has been detected on the
Video Processor. This will affect
services and the error is being
recovered. See log for more details.
1 010C0008
CE-x
Analogue
Module
critical

Table of Contents

Related product manuals