Getting Started
EN/LZT 790 0023/1 R16A
3-11
Parameter Values Description Comments
IGMP v2 [default] Uses version 2 of the IGMP protocol
Physical Control Interface <n>
Default MAC Address aa:bb:cc:dd:ee:ff
The MAC address of the Gex
interface.
Read only parameter
Link Status Link Up (1000)
Link is up and the link speed is 1000
Mbps.
Read only parameter
Link Up (100)
Link is up and the link speed is 100
Mbps.
Link Down Link is down.
Link Up Time days : hours : mins : secs
The length of time that the link has
been up. If the link goes down this
value is reset to 0.
Read only parameter
TX Packets Number of IP packets transmitted Read only parameter
RX Packets Number of IP packets received Read only parameter
IP Address aaa.bbb.ccc.ddd
IP address of the physical control
interface
If set to 0.0.0.0 control interfaces will
only respond to virtual IP address
Setting the physical IP address allows
the interface to be pinged to validate
the connection. This is not intended
not be used as the IP address for
configuration and control.
Must be on the same subnet and
gateway as the virtual interface.
3.7 How to Configure Ethernet Data Ports
Overview
Four gigabit Ethernet ports are provided for data input and output.
Figure 3.3 Ethernet Data Port Numbering

Table of Contents