Web GUI Control
EN/LZT 790 0023/1 R16A
5-65
Splicing Component
The following parameters are available on the Component tab of the Properties
widget on the Service Configuration page when an SCTE 35 stream is selected in
the Outputs widget. The same parameters can be accessed through the
Output/<output name>/Transport Stream ID: <n>/Service List/<service
name>/Component List/<component name> menu on the front panel.
Table 5.30 Slicing Component Parameters
Parameter Values Description
PID 32 to 8190 Sets the packet identifier associated with the component.
Bit Rate Weighting Fixed
Specifies the weight associated to the component in the
Bit Rate Tracking algorithm. For audio stream, this is Fixed
and read only.
5.5.3.1.4 Teletext Stream Configuration
This section describes the parameters for setting up Teletext.
Teletext
This section gives the parameters that have an effect on how Teletext is transmitted.
The parameters listed are available on the Teletext tab of the Properties widget on
the Service Configuration page when a Teletext stream is selected in the Outputs
widget. The same parameters can be accessed through the Advanced/CE-
a/Video/Video 1/Input/VBI Extraction/Teletext menu on the front panel.
Table 5.31 Teletext Parameters
Parameter Values Description
Teletext Source Off, OP-47 (Max 300kb/s), VANC Teletext
Controls the source from where Teletext is extracted,
including encapsulation method where appropriate.
Teletext Packetisation
Normal (ETS 300-472) - Data on Teletext
Component, Legacy (ETS 301-775) - Data on
VBI Component
Controls how the Teletext data is packetized in to a
component data stream.
SMPTE2031 Max. No.
Teletext
3, 7, 11, 15, 36
Defines the maximum number of Teletext lines inserted.
Available only if VANC Teletext is selected for Teletext
Source.
SMPTE2031 Teletext
Present
Yes, No
Displays whether Teletext is found in the SDI stream.
Available only if VANC Teletext is selected for Teletext
Source. Read only parameter.
Min # Teletext Packets 0 to 3
Defines the minimum number of Teletext packets
generated per field, even if there is no Teletext data.
PTS On Teletext Off, On
Controls whether a PTS value is included in the output
Teletext packets.
Teletext Descriptor Page List / Teletext Descriptor Page
Teletext Page Type
Off, Initial Page, Subtitle Page, Additional
Information Page, Programme Schedule Page,
Heading Impaired Subtitle Page
The page type of the Teletext descriptor.