EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
103 (200)
g. In the “Command” column, set all entries to “modify”, as follows:-
Double click on the 1
st
entry in this column and from the drop-down list
select the “modify” option. Select the 1
st
entry, then left-click & drag down
to the bottom of the column to highlight all entries. Right click & select
Replicate cell”, all entries in the “Command column should now be set to
modify”. Check that all entries have been changed correctly.
h. Select Apply All Rows” from the bottom LHS of the screen. Wait until all
the rows turn Green.
i. Select Read Network” near the top of the screen, this will confirm the
configuration. If there are any incorrect entries they will be highlighted at
this point.