7.14 Configure ADSL Profiles
Note: This section ONLY applies to ADSL Profiles.
a. From the main LCT screen, select the path Configuration > xDSL
Profiles. The “Line Profile Management” window will open.
b. Select File” then “Open”, then navigate to the relevant folder and select
the template file “xDSL Profile Management - xDSL Line Profile.ap”.
Select “Open”, then the following screen will be displayed which will default
to the “Channel” tab:-
c. In the “Ne Name” column the template will load the default OOB IP
address of 150.150.150.4, the Node being commissioned is likely to have a
different one allocated to it. The Out Of Band IP Address is determined by
the DLE ID, refer to Section 5.5. Change the address (if necessary) in this
column for all entries, as follows:-
Change the 1
st
entry in this column to the correct IP address, select the 1
st
entry, then left-click the 1
st
entry & drag down to the bottom of the column
to highlight all entries. Right click & select “Replicate cell”, all entries in the
Ne Name” column will now be set to the required OOB IP Address.