EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
85 (200)
d. Click on the “Accept selected entries” button, the display will revert back
to the “Static VLAN Members” table.
For the SHDSL card(s), new “intLag” interfaces will now be created in the
“DATA_INBAND” S-VLAN, as shown in the following typical screen.
e. In the “Command” column, against the new “intlag//1/..” entries just
created, double click on the empty field and select the “addPort” option
from the drop-down list. All new entries in the “Command” column will now
be set to “addPort”.
f. Select Apply All” from the bottom LHS of the screen. The rows will turn
Green and under the “Result” column the field should display “OK”.
g. Select Read Network” near the top of the screen, this will confirm the
configuration, if there are any incorrect entries they will be highlighted at
this point.
7.7.3 Create S-VLANs for POTS Cards (If required)
An “intLag” interface must be created for each POTS card against the appropriate
VOIP_GWx name for the relevant slot. Proceed as follows:-
a. If the slot 3 POTS card is to be configured, double left-click on the
ethG//1/1/1” entry in “User Port Interface Name” column against
VOIP_GW1”. Refer to the table below for POTS slot vs. S-VLAN names.