EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
34 (200)
3.3.1 PC Connection Cables for Commissioning
Cable for connecting the Local Controller Ethernet Port to the EDA 2530 Common
Part Card. .
RJ45 Crossover Cable - Local Controller Ethernet Port to EDA 2530
Common Part Card
RJ45 Connector RJ45 Connector
Signal Pin Pin Signal
TD+ 1 3 RD+
TD- 2 6 RD-
RD+ 3 1 TD+
RD- 6 2 TD-
TD = Transmit Data RD = Receive Data
No. Description Code Qty
1 A PC to run EDA2530 LCT application (Min specifications
Pentium III 750MHz, 542Mb Ram, 200Mbyte free space,
CD-ROM, resolution 1024x768). Operating System XP or
Vista.
1
2 EDA 2530 Local Controller Software CD for the release of
the EDA 2530 being commissioned. (S38-xxxx/xx.xx.xx)
1
3 RJ45 Crossover cable for connecting the Local Controller
Ethernet Port to the EDA 2530. Refer to Section 3.3.1.
(Q4273) 1
4 RS232 Serial Cable Set, used to connect the Common
Part Unit (CP) RS232 interface to the PC serial COM
port. (Refer to Section 3.4.1 for details)
CWA0002
1
5 Digital Multimeter 1
6 “Golden Modem” multi-level xDSL service tester, with
ADSL /G.SHDSL module interfaces. Capable of ATU-R
and STU-R modem operation modes or an ADSL
modem, Eg. Linksys AM200 ADSL2+ modem.
1
7 SHDSL Modem Eg. Billion BiPAC 8520 up to 4.6Mbps
(4-wire SHDSL) Bridge/Router
1
8 Optical Power Meter with adapter lead for LC connection. 1
9 HDF block 2 pole to RJ11 test cord (Banana plugs) CWA006 1
10 HDF block 2 pole to RJ11 test cord CWA007 1
11 HDF Krone block 2 pole to RJ11 test cord CWA008 1
12 Butt Telephone Test Set with either internal or external
DSL/POTS filtering. Eg. Fluke TS-25D Telephone Test
kit. (Which includes DSL/POTS filtering)
1
13 RJ11 ADSL filter for Test Telephone 1