EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
72 (200)
7.2 Configure CP Ethernet Interfaces
7.2.1 Configure CP Port 1
Configure CP Port 1 GigE interface to be the In Band Management interface.
a. Right click on the CP Card and select Ethernet Lines from the sub menu.
b. Select the “Port 1” button, then click on “Configure”, the following window
will be displayed:-
c. From the “Configuration” folder tick the Local In-Band Mng tick box. Then
click on the “Apply” button that is immediately to the left of the tick box.
d. Select the “MAU” folder, the following window will be displayed:-