EasyManua.ls Logo

Ericsson EDA 2530 - Page 71

Ericsson EDA 2530
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EDA 2530 Commissioning Procedure for Cable and Wireless Access
1/153 22-FGC 101 0239/2 Uen Rev J 2010-04-01
© Ericsson AB 2010
Commercial in confidence
71 (200)
Change the “SFP Medium Type” to Dual Fibre.
Set the “SFP Laser Wave Length (nm)” to 1310 for example. (Verify the
setting against the SID document for CP Port 1 SFP1 module.)
Leave “SFP connected to Y-Coupler” set to false (default).
f. Select the “Apply” button in the top right-hand corner to modify the
configuration.
g. Select Refresh”, then “Close” to return to the “CP-IP SFP/Port Provisioning”
screen.
h. If the SFP2, SFP3, SFP4 module(s) have not configured correctly then repeat
the above steps c. to g. for CP Ports “1/1/2/2”, “1/1/2/3”, & “1/1/2/4” (as
appropriate). The settings are to be the same as Port “1/1/2/1” except for
setting the wave length to 850nm.
i. Select Refresh” on the “CP-IP SFP/Port Provisioning” screen.
j. Check on the table that the parameters are correct with the type of SFP
installed, check that the SFP(s) are alarm free, ie the Alarm Status is ‘not
alarmed’.
k. Select Close” to return to the main LCT window.

Table of Contents